In the water quality improvement industry, membranes are simply defined as physical barriers that separate solutions and allow passage of contaminants within a certain range of size, molecular mass, or even charge polarity and strength. When driving pressure is applied, certain contaminants will be “selectively rejected” or “concentrated” by the membrane (depending on the membrane material/s, pore size and electrical charge) while water and unrejected contaminants will pass through as a permeate stream. Membrane separation technology is an invaluable resource for residential, commercial and industrial water treatment applications.

 

Flow Configuration

Separation membranes are typically operated in “dead-end” or crossflow configuration. In dead-end configuration, the rejected contaminants concentrate into the influent stream and eventually accumulate against the surface and pores of the membrane. Naturally, the concentrated contaminants will inevitably clog the membrane pores entirely, so this process is reserved for applications where the cost/inconvenience of replacing fouled membrane sheets is less important than losing any of the raw fluid or where the engineered process flow design specifically calls for it. A growing segment of “dead-end” configuration is backwashable tubular or “hollow fiber” construction, which is significantly less sensitive to fouling than membrane sheets. Look for increasing market penetration of this technology as the manufacture of these tubes become more reliable and cost-effective.

In crossflow filtration, the membrane geometry is designed for contaminants to be scrubbed away from the membrane surface when the concentrated discharge stream is passed to drain or a secondary process. Leveraging the principles of Fick’s laws of diffusion, designers can manipulate macromolecule concentration molecules at the membrane surface as a function of the velocity of fluid that is flowing parallel to it.

 

Membrane materials and element construction

Crossflow technology is cost-effective and practical due to durable organic polymeric materials.

Those of you who have been around the industry for a few years will remember Cellulose Triacetate (CTA) membranes that were once ubiquitous. A game-changer popularized in the mid-1990’s was Thin Film Composite (TFC) which lowered total cost of ownership and increased flux at lower driving pressures. Composite membranes can be made from a number of materials, such as polyethersulfone (PES), polysulfone (PSU), polyphenylsulfone (PPSU), polytetrafluoroethylene (PTFE), polyvinyldene fluoride (PVDF), and even polypropylene (PP). The vast majority of installations these days utilize composite membranes while other materials such as ceramics made from Silica, Aluminum, Titanium and other materials are only where pH, temperature, abrasiveness, cleaning chemistry, or other operational parameters prohibit the use of polymers.

Polymeric membranes can be manufactured symmetrically or asymmetrically, depending on the intended use and intended use. Contrary to popular belief, there are many ways to build a crossflow membrane, including type of polymer, length of membrane leaves, membrane support configuration and membrane density. These configuration options are significant in mission-critical operations, and also important when selecting regular water-filtration membranes that you are going to stake your reputation on.

Today’s mainstream membrane separation technologies can be separated into four broad categories of separation by relative contaminant exclusion size:

Reverse Osmosis (RO) – Sometimes called “hyperfiltration”, reverse osmosis is the finest form of filtration used today.  The membrane pores are small enough to enable the reversal of osmotic pressure through ionic diffusion when sufficient external energy (pumping pressure) is applied. This reversal of osmotic pressure actually drives pure water away from molecular contaminants and enables processes like seawater desalination where sodium ions are physically removed from water; greening the desert and bringing clean, safe drinking water to places where it was previously impractical. Reverse Osmosis is also used industrially in many innovative applications such as concentrating fruit juice, concentrating whey protein, and of course wastewater sludge dewatering.

Nanofiltration (NF) – Developed as an extension of RO, NF functions according to the same principles of ionic diffusion as RO, but with a pore-size configuration and slight surface charge that allows passage of all contaminants except divalent and larger ions. Monovalent ions such as sodium and potassium pass right through an NF membrane, allowing it to be used as a highly effective salt-free softening technology without the complications of Reverse Osmosis.  NF is also highly effective at addressing semi-volatile organics such as pesticides, and removing color from water.

Ultrafiltration (UF) – Ultrafiltration is a true physical exclusion process and doesn’t rely on osmotic principles. UF membranes are categorized by their molecular cut-off rating (MWCO). The typical range of MWCO’s for UF is from 1,000 to 1,000,000 Dalton which correlates to approximately 0.005 – 0.1 micron (µm). UF is extremely effective in removing suspended solids, colloids, bacteria, virus, cysts, and high molecular weight organics like tannins. UF membranes are operated in dead-end configuration, occasional flush (forward flush and/or backflush), or crossflow configuration. Membrane configuration can vary between manufacturers, but the “hollow fiber” type is the most commonly used. Membranes in the hollow fiber type are cast into small diameter tubes or straws. Thousands of these straws are bundled together and the ends are bonded/potted into an epoxy bulkhead. The bundles are then sealed into a housing which is usually PVC, fiberglass,  or stainless steel. The sealed potting creates a separate, sealed space that isolates access to the inside of the fibers from the outside. This membrane and housing combination is called a module. A number of UF membrane assemblies on the market are BioVir certified for log reduction of pathogens in drinking water such as bacteria and virus, enabling dealers to provide safe drinking water more cost-effectively and efficiently than ever before.

Microfiltration (MF) – Microfiltration technology has been successfully employed in both crossfiltration spiral-wound, occasional flush hollow fiber (forward flush and/or backflush), and dead-end plate & frame configurations, depending on the nature of the application and space available. This membrane technology typically has an exclusion size of 0.2µm – 1 µm and is very well suited for the removal of particulates, turbidity, suspended solids, as well as certain pathogens such as Cryptosporidium and Giardia. MF has an established industrial track-record for sterile clarification of wine and beer, whey concentration and fruit juice sterilization. In the wastewater treatment field, microfiltration is invaluable for dewatering flocculant sludge, and economically lowering BOD and COD in discharge streams. Microfiltration is also extremely effective in protecting other downstream membrane separators.

Typical rejection capabilities
  Water Monovalent Ions Multivalent Ions Macro-molecules Suspended Solids
Reverse Osmosis  
Nanofiltration    
Ultrafiltration      
Microfiltration        

 

Pretreatment and Maintenance

It is vitally important to select the appropriate pretreatment for the membrane separation process being used. Composite polymeric membranes are very sensitive to oxidative damage, so special care should be taken to ensure that chlorine, ozone, and other oxidative disinfectants are removed from the raw water before being processed by the membrane. Careful consideration should also be given to macro particles and organic/inorganic contaminants in the water stream that could affect proper membrane function. As a good general rule, the smaller the pore size, the greater amount of physical pretreatment required to ensure long runtimes and economic operation.

Regardless of the membrane pore size, operational fouling is almost inevitable, even with pre-treatment. The types and amounts of fouling are dependent on many different factors, such as feed water chemistry, membrane type, membrane materials and operational process. The most common types of membrane fouling are scale precipitation and biofouling. Fouling causes a decrease in flux (passage of purified water), which in turn requires greater pressure against the membrane to produce a satisfactory permeate flow rate. As fouling worsens, the increased pressure (energy) requirement will cause the operating cost to increase significantly and possibly even blind the membrane completely leading to significant damage and operational failure.

Many innovative membrane antiscalant, metal sequestering, microflocculanting, and CIP (Clean-in-Place) compounds are available to help keep your membrane/s clean and operating as energy-efficiently as possible. Some good questions to ask your supplier before using a pre-treatment chemical:

  • Is it 100% compatible with the membrane/s in the application?
  • Can it react adversely with any other contaminants in the feed water like iron, heavy
  • metals, and other inhibitor chemicals?
  • What are the recommended dosing rates and maximum dosing rates?
  • What are the projected limits of solubility for individual scaling and fouling components?
  • Are there any special discharge/reclamation regulations or concerns?
  • Do you offer technical support services like water testing, chemical analyses, and membrane autopsies?

 

Emerging Contaminants

Emerging contaminants have been in our water for a long time, and we only now have the equipment and methods for detecting these low levels of contaminants in water.  More than 7 million recognized chemical compounds are known to be in existence, and approximately 80,000 of them are in common use worldwide. Regulatory agencies have no idea exactly how many specific compounds are used in consumer goods, nor what specific combinations are used in each product. There are also a host of secondary compounds that form when chemicals are exposed to oxidizers and other reagents.  In the 21st century, it is safe to say that all water everywhere is “contaminated” with some kind of man-made chemical at some level. Towards the end of the last century, evidence began to accumulate that chemicals such as pesticides, surfactants (used in detergents) and synthetic birth control drugs were causing skewed sex ratios, reproductive disorders, and population declines in frogs, alligators and fish. Some researchers have suggested that Antibiotics and Antimicrobials can pose a serious threat to human health by enhancing the antibiotic resistance of disease-causing microorganisms due to their (over)use in products such as soaps, mouthwash, toothpaste, and of course the ubiquitous “hand sanitizer”.  Membrane separations are proving to be invaluable in the fight against emerging contaminants, since Reverse Osmosis technology paired with intelligent oxidation and effective absoption/adsoption can be highly effective in rejecting organo-synthetic molecules from water.

 

Emerging Technologies

As we continue to see more misguided attempts at softener bans and a continued emphasis on minimizing our net environmental impact, the need for more environmentally friendly water quality improvement technologies becomes glaringly apparent.  Membrane separations are highly effective in reducing chloride discharge and in chemical requirements. Many dealers are using Nanofiltration and blended Reverse Osmosis systems as “salt-free softeners” – providing their clients with water that has Hardness levels below 17.1 mg/L (1 Grain per Gallon). New innovative materials like synthetic ceramics and polymers as well as enhanced spacers designs and uniform thin film fabrication techniques allow for continuous improvements in membrane longevity, reduction in driving energy requirements, and minimization of fouling while continuing to lower the initial acquisition-cost and total cost of ownership.

 

Environmentally Friendly Technology

Some well-meaning but misinformed people accuse membrane separation systems of being “wasteful”, since water is used to clean the membrane/s during operation. I disagree with the negative description of drain concentrate water as “wasted water”, since it really is not. Saying that a membrane separator wastes water is no different than saying that a tree dropping its unpicked fruit is wasteful. The fruit returns nutrients to the earth and feeds the tree, which then grows more fruit. Discharge water from a membrane separation system is also not “lost forever”, it will return through the building’s drainage system to a municipal plant, or back to the earth in an off-grid application or can be repurposed onsite by design. We obviously can’t ignore the “opportunity cost” of the water though, since it must be cleaned, stored, treated, pressurized, and distributed before it enters the membrane separator. Since the discharge from a potable water membrane separator is also sanitary potable water (this is obviously not considered wastewater, since it is never in contact with soils, dirt, or biological contaminants; it is merely concentrated clean water), much of this opportunity cost can be recovered through innovative reuse techniques such as graywater recovery, blending with harvested rainwater, repurposing in secondary process or used as landscape irrigation. Recent innovations in concentrate energy recovery and storage are also helpful in demonstrating how truly efficient membrane separation technology can be.

 

Educate Yourself

Properly implemented membrane separation systems are a truly environmentally method to improving water quality and an invaluable tool for water quality improvement professionals. It is critically important that you either secure the education you need to ensure proper system selection, design and deployment, or work with vendors who you can rely on to help before getting yourself into trouble by making uninformed decisions.

The WQA’s Modular Education Program (MEP) offers a great starting-point for learning more about RO and other membrane separation technologies to help you do a better job.

 

Image Credits: The Innovative Water Project

 

 

Glossary:

Dalton – The unified atomic mass unit (symbol: u) or Dalton (symbol: Da) is the standard unit that is used for indicating mass on an atomic or molecular scale (atomic mass). One unified atomic mass unit is approximately the mass of one nucleon (either a single proton or neutron) and is numerically equivalent to 1 g/mol. It is defined as one twelfth of the mass of an unbound neutral atom of carbon-12 in its nuclear and electronic ground state, and has a value of 1.660539040(20) × 10−27kg.

Fick’s laws of diffusion were derived by Adolf Fick in 1855. Expressed as follows: They can be used to solve for the diffusion coefficient, “D”. Fick’s first law can be used to derive his second law which in turn is identical to the diffusion equation. Fick’s first law relates the diffusive flux to the concentration under the assumption of steady state. It postulates the concept that a solute will move from a region of high concentration to a region of low concentration across a concentration gradient. Fick’s second law (non-steady state Diffusion) predicts how diffusion causes the concentration to change with time. While Fick holds that flux is directly proportional to the concentration gradient, the diffusion coefficient “D” is affected by temperature and pressure.

Flux is the rate of mass transfer across unit surface area of barrier and mathematically expressed as:    J atoms/area/time.

Micron (µm) – One millionth of a meter. One Inch is equal to 25,400 micron.

Plate and Frame – Also known as a “membrane filter plate”. This type of filter press typically consists of alternating plates and frames supported by rails. A pressure pump is used to deliver liquid to be filtered (slurry) into each of the separating chambers. For each of the individual separating chambers, there is one hollow filter frame separated from two filter plates by filter cloths. The slurry flows through a port in each individual frame, and the filter cakes are accumulated in the hollow frame. As the filter cake thickens, the filter resistance increases as well. The filtration process is halted once the optimum pressure difference is reached. The filtrate that passes through filter cloth is collected through collection pipes and stored in the filter tank. Filter cake (suspended solid) accumulation occurs at the hollow plate frame, then being separated at the filter plates by pulling the plate and frame filter press apart. The cakes then fall off from those plates and are discharged to the final collection point.

One Reply to “Membrane Separation – Things to know”

Leave a Reply